I'm LongbridgeAI, I can summarize articles.Anteris Technologies Global Corp. (NASDAQ:AVR) on Sunday reported positive one-year clinical and hemodynamic results for its DurAVR Transcatheter Heart Valve (THV) in 100 patients with severe aortic stenosis and small aortic annuli (404 ± 37 mm2).
The findings highlight strong valve durability and low heart failure hospitalizations in an anatomy prone to elevated gradients and prosthesis-patient mismatch (PPM).
Strong Hemodynamics And Low Heart Failure Hospitalizations
At one year, only 1% of patients required hospitalization for heart failure, beating the mid-to-high single-digit rates seen in contemporary trials of marketed valves.
The DurAVR THV lowered the mean pressure gradient from 48.1 mmHg at baseline to 8.9 mmHg and expanded mean effective orifice area (EOA) from 0.8 cm2 to 2.2 cm2, matching its 30-day results from 2025.
Read Also: Edwards Lifesciences Secures FDA Approval for First Expandable Pediatric Heart Valve
Clinicians observed zero moderate or severe hemodynamic valve deterioration and no moderate or severe paravalvular leak (PVL) through one year.
The study recorded zero valve-related deaths, and 97% of patients avoided moderate or severe PPM at 30 days.
Symptom Relief In Complex Aortic Stenosis Patients
The valve delivered these outcomes in a clinically complex group where 61% of patients began in New York Heart Association (NYHA) class III/IV, with a mean STS-PROM score of 4.7%, heavy calcification, and 9% bicuspid anatomy.
Investigators pooled patients from the U.S. and European EMBARK and early feasibility studies, following 30-day data presentations at PCR London Valves 2025.
By one year, 81% of patients reported symptom improvement, lifting NYHA class I/II representation from 39% at baseline to 96%. All-cause mortality reached 6%—comprising two cardiovascular deaths, two non-cardiac infections, one cancer, and one car accident—while stroke hit 3% and new permanent pacemaker implantation stood at 9%.
Left Ventricular Remodeling And Pivotal PARADIGM Trial
In a 64-patient cardiac magnetic resonance substudy, left ventricular mass regressed by 24% at one year, matching levels in controls without aortic valve disease and confirming sustained ventricular unloading.
Researchers actively enroll patients across the United States and Europe in the pivotal PARADIGM Trial (NCT07194265), comparing DurAVR THV head-to-head against commercial TAVR valves.
AVR Price Action: Anteris Technologies Glb shares were up 16.63% at $5.82 at the time of publication on Monday, according to Benzinga Pro data.